• EN
  • DA

Danish NationalResearch Database

  • Publications
  • Researchers
Example Finds records
water{} containing the word "water".
water supplies"{}" containing the phrase "water supplies".
author:"Doe, John"author:"{}" containing the phrase "Doe, John" in the author field.
title:IEEEtitle:{} containing the word "IEEE" in the title field.
bech{} containing the word "bech".
marie bech"{}" containing the phrase "marie bech".
orcid:0000-0002-5429-5292orcid:{} Having a particular ORCID
Need more help? Advanced search tutorial
  • Selected (0)
  • History

Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Uribe, Sergio ;
    Close
    King's College London
  • Beerbaum, Philipp ;
    Close
    King's College London
  • Sørensen, Thomas Sangild ;
    Close
    Orcid logo0000-0002-8482-7667
    unknown
  • Rasmusson, Allan ;
    Close
    unknown
  • Razavi, Reza ;
    Close
    King's College London
  • Schaeffter, Tobias
    Close
    King's College London
DOI:
10.1002/mrm.22090
Abstract:
Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify and improve hemodynamic assessment. This has been a challenge because compensation of respiratory motion is difficult to achieve, but it is paramount to limit artifacts and improve accuracy. In this work we propose a self-gating technique for respiratory motion-compensation integrated into a whole-heart 4D flow acquisition that overcomes these challenges. Flow components are measured in all three directions for each pixel over the complete cardiac cycle, and 1D volume projections are obtained at certain time intervals for respiratory gating in real time during the acquisition. The technique was tested in 15 volunteers, in which stroke volumes (SVs) in the great arteries showed excellent agreement with standard 2D phase-contrast (PC) scans. In contrast, nongated 4D flow with two averages had substantial disagreement with 2D flow. Applied to patients with congenital cardiac left-to-right shunting, the precision of flux data was highly beneficial. The methodology presented here has the potential to allow a complete study of flow pathophysiology of the thoracic cardiovascular system from a single free-breathing scan.
Type:
Journal article
Language:
English
Published in:
Magnetic Resonance in Medicine, 2009, Vol 62, Issue 4, p. 984-992
Keywords:
4D flow imaging; whole heart; self-gating; Hemodynamic assessment; congenital heart disease
Main Research Area:
Science/technology
Publication Status:
Published
Review type:
Peer Review
Submission year:
2009
Scientific Level:
Scientific
ID:
3774040

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • Aarhus university.en
Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en