Restenosis in coronary bare metal stents. Importance of time to follow-up: a comparison of coronary angiograms 6 months and 4 years after implantation

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Jørgensen, Erik ;
    Close
    unknown
  • Helqvist, Steffen ;
    Close
    unknown
  • Kløvgaard, Lene ;
    Close
    unknown
  • Kastrup, Jens ;
    Close
    unknown
  • Clemmensen, Peter ;
    Close
    unknown
  • Holmvang, Lene ;
    Close
    unknown
  • Engstrøm, Thomas ;
    Close
    unknown
  • Saunamaki, Kari ;
    Close
    unknown
  • Kelbaek, Henning
    Close
    unknown
DOI:
10.1080/14017430802582602
Abstract:
Objectives. Angiographic late lumen loss measured 6 to 9 month after bare metal stent implantation in the coronary arteries is a validated restenosis parameter. Design. We performed a second angiographic follow-up after 4 years in event free survivors from the DANSTENT trial cohort. Results. Quantitative comparison of paired coronary angiograms at 6 months and 4 years showed a reduction of late loss from 0.68+/-0.52mm to 0.42 (+/-0.52) (mean difference 0.26 (0.17 to 0.36), p<0.0001). Minimal instent lumen diameter had increased from 2.39+/-0.62mm to 2.64+/-0.56mm (mean difference: -0.24mm, 95% confidence interval: -0.34mm to -0.14mm, p<0.0001). Instent diameter stenosis decreased from 24.8+/-14.2% to 18.6+/-9.3% (mean difference 6.16%, 95% confidence interval: 2.82 to 9.48%, p=0.0006). This observed spontaneous decrease of instent restenosis corresponds to a 19% increase of minimal cross-sectional vessel area and a 39% reduction of the binary restenosis rate over time. Conclusions. Instent late lumen loss in bare metal stents decreases spontaneously over time. Maturation of early hyperplastic tissue reaction after stent implantation with subsequent thinning of fibrotic tissue might explain this phenomenon Udgivelsesdato: 2008/11/23
Type:
Journal article
Language:
English
Published in:
Scandinavian Cardiovascular Journal, 2008, Vol 43, Issue 2, p. 87-93
Main Research Area:
Medical science
Publication Status:
Published
Review type:
Peer Review
Submission year:
2008
Scientific Level:
Scientific
ID:
19906607

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • Copenhagen university.en
Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en