Unusual balloon rupture during direct stenting with a TaxusExpress stent in a venous graft complicated by vessel rupture: a device-related fatal event

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Christiansen, Evald H
    Close
    unknown
DOI:
10.1111/j.1540-8183.2007.00237.x
Abstract:
A 70-year-old male with a prior coronary artery bypass operation presented with increasing episodes of chest pain. Coronary angiography revealed severe disease of the left anterior descending artery (LAD), CX, and RCA. A left internal mammary artery to LAD was patent. A jump venous graft, with four distal anastomoses, had two significant stenoses. Percutaneous coronary intervention with distal protection, and direct stenting with a drug-eluting stent, was planned. A 3.00 x 16 mm TaxusExpress (Boston Scientific) was used. At an inflation pressure of 10 atm the stent balloon seemed to extend 20 mm proximally with a diameter of 4.5 mm, and the balloon ruptured. Angiography showed rupture of the vessel proximal to the implanted stent, and the patient developed severe hypotension. The rupture was treated with a covered stent and pericardiocentesis was performed with evacuation of 600 mL blood. However, it was not possible to resuscitate the patient, who died due to severe pump failure and incessant ventricular fibrillation. Udgivelsesdato: 2007-Feb
Type:
Journal article
Language:
English
Published in:
Journal of Interventional Cardiology, 2007, Vol 20, Issue 1, p. 23-5
Keywords:
Angioplasty, Transluminal, Percutaneous Coronary; Coronary Aneurysm; Coronary Angiography; Equipment Failure; Fatal Outcome; Graft Occlusion, Vascular; Humans; Internal Mammary-Coronary Artery Anastomosis; Male; Middle Aged; Rupture; Severity of Illness Index; Stents
Main Research Area:
Medical science
Publication Status:
Published
Review type:
Peer Review
Submission year:
2007
Scientific Level:
Scientific
ID:
109352540

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • Aarhus university.en
Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en