• EN
  • DA

Danish NationalResearch Database

  • Publications
  • Researchers
Example Finds records
water{} containing the word "water".
water supplies"{}" containing the phrase "water supplies".
author:"Doe, John"author:"{}" containing the phrase "Doe, John" in the author field.
title:IEEEtitle:{} containing the word "IEEE" in the title field.
bech{} containing the word "bech".
marie bech"{}" containing the phrase "marie bech".
orcid:0000-0002-5429-5292orcid:{} Having a particular ORCID
Need more help? Advanced search tutorial
  • Selected (0)
  • History

ANALYSIS OF MEASURED AND MODELED SOLAR RADIATION AT THE TARS SOLAR HEATING PLANT IN DENMARK

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Tian, Zhiyong ;
    Close
    Orcid logo0000-0001-7113-9702
    Department of Civil Engineering, Technical University of Denmark
  • Perers, Bengt ;
    Close
    Orcid logo0000-0002-0436-9687
    Department of Civil Engineering, Technical University of Denmark
  • Furbo, Simon ;
    Close
    Orcid logo0000-0003-2578-4780
    Department of Civil Engineering, Technical University of Denmark
  • Fan, Jianhua
    Close
    Orcid logo0000-0003-0936-6677
    Department of Civil Engineering, Technical University of Denmark
DOI:
10.18086/eurosun.2016.09.12
Abstract:
A novel combined solar heating plant with tracking parabolic trough collectors (PTC) and flat plate collectors (FPC) has been constructed and put into operation in Tars, 30 km north of Aalborg, Denmark in August 2015. To assess the operation performance of the plant, detailed parameters, such as solar radiation, inlet and outlet temperature for the solar collector field, flow rate and pressure, ambient temperature, Wind speed and wind direction were measured. Global horizontal radiation, direct normal irradiation (DNI) and total radiation on the tilted collector plane of the flat plate collector field have been measured in Tars solar heating plant. To determine the accuracy of modeled and measured solar radiation in Tars solar heating plant, monthly comparisons of measured and calculated radiation using 6 empirical models have been carried out. Comparisons of measured and modeled total radiation on the tilted surface with different methods were also studied. The results have shown that the DTU model could he used to calculate the diffuse radiation on horizontal surface and the anisotropic models (Perez 1988 model and Perez 1999 model) with only 1% and 2% disagreement with measured data respectively were the most accurate to he used for the calculation of total radiation on the tilted collector surface under Danish climate conditions only based on global horizontal radiation.
Type:
Conference paper
Language:
English
Published in:
Proceedings of the 11th Ises Eurosun 2016 Conference, 2017, p. 1536-1542
Keywords:
Tars solar heating plant; solar radiation; diffuse radiation; total radiation on tilted surfaces; measurements; calculations
Main Research Area:
Science/technology
Conference:
Eurosun 2016
Submission year:
2018
ID:
2398080327

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • Technical university of dk

Metrics

Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en