• EN
  • DA

Danish NationalResearch Database

  • Publications
  • Researchers
Example Finds records
water{} containing the word "water".
water supplies"{}" containing the phrase "water supplies".
author:"Doe, John"author:"{}" containing the phrase "Doe, John" in the author field.
title:IEEEtitle:{} containing the word "IEEE" in the title field.
bech{} containing the word "bech".
marie bech"{}" containing the phrase "marie bech".
orcid:0000-0002-5429-5292orcid:{} Having a particular ORCID
Need more help? Advanced search tutorial
  • Selected (0)
  • History

Extraction of polycyclic aromatic hydrocarbons from smoked fish using pressurized liquid extraction with integrated fat removal

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Lund, Mette ;
    Close
    University of Copenhagen
  • Duedahl-Olesen, Lene ;
    Close
    Orcid logo0000-0002-3162-0101
    National Food Institute, Technical University of Denmark
  • Christensen, Jan H.
    Close
    University of Copenhagen
DOI:
10.1016/j.talanta.2009.02.048
Abstract:
Quantification of polycyclic aromatic hydrocarbons (PAHs) in smoked fish products often requires multiple clean-up steps to remove fat and other compounds that may interfere with the chemical analysis. We present a novel pressurized liquid extraction (PLE) method that integrates exhaustive extraction with fat retention in one single analytical step. The PLE parameters: type of fat retainer, flush volume, solvent composition, fat-to-fat retainer ratio (FFR), and the dimensions of the extraction cells were the most important factors for obtaining fat-free extracts with high recoveries of PAHs. A 100 mL extraction cell filled with 18 g activated silica gel, dichloromethane:hexane (15:85, v/v) as extraction solvent, FFR of 0.025 and 100% flush volume was the best analytical setup for integrated extraction and fat retention. The one-step procedure provided a more rapid and cost-efficient alternative with minimization of waste generation compared to the standard reference method that is based on a multi-step procedure. Furthermore, the analytical quality of the two methods are comparable, while the new integrated approach for extraction and cleanup is less prone to analytical errors (random and systematic) because of fewer analytical steps.
Type:
Journal article
Language:
English
Published in:
Talanta: the International Journal of Pure and Applied Analytical Chemistry, 2009, Vol 79, Issue 1, p. 10-15
Keywords:
Principal component analysis; Pressurized liquid extraction; Polycyclic aromatic hydrocarbons; Method validation; Smoked fish
Main Research Area:
Science/technology
Publication Status:
Published
Review type:
Peer Review
Submission year:
2009
Scientific Level:
Scientific
ID:
2381115

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institutions

  • Technical university of dk
  • Copenhagen university.en
Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en