Positive predictive value of device-detected atrial high-rate episodes at different rates and durations

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Kaufman, Elizabeth S ;
    Close
    unknown
  • Israel, Carsten W ;
    Close
    unknown
  • Nair, Girish M ;
    Close
    unknown
  • Armaganijan, Luciana ;
    Close
    unknown
  • Divakaramenon, Syamkumar ;
    Close
    unknown
  • Mairesse, Georges H ;
    Close
    unknown
  • Brandes, Axel ;
    Close
    Cardiology, Department of Clinical Research, Faculty of Health Sciences, SDU
  • Crystal, Eugene ;
    Close
    unknown
  • Costantini, Otto ;
    Close
    unknown
  • Sandhu, Roopinder K ;
    Close
    unknown
  • Parkash, Ratika ;
    Close
    unknown
  • Connolly, Stuart J ;
    Close
    unknown
  • Hohnloser, Stefan H ;
    Close
    unknown
  • Healey, Jeff S
    Close
    unknown
Subtitle:
An analysis from ASSERT
DOI:
10.1016/j.hrthm.2012.03.017
Abstract:
BACKGROUND: Pacemakers can automatically identify and catalog atrial high-rate episodes (AHREs). While most AHREs represent true atrial tachyarrhythmia/atrial fibrillation (AT/AF), a review of stored electrograms suggests that a substantial proportion do not. As AHREs may lead to the initiation of oral anticoagulation, it is crucial to understand the relationship between AHREs and true AT/AF. OBJECTIVE: To compare the positive predictive value of AHREs for electrogram-confirmed AT/AF for various atrial rates and episode durations. METHODS: By using data from 2580 patients who participated in the ASymptomatic atrial fibrillation and Stroke Evaluation in pacemaker patients and the AF Reduction atrial pacing Trial, all AHREs >6 minutes and >190 beats/min with available electrograms were reviewed to determine whether they represented true AT/AF. The positive predictive value of these AHREs was assessed for episode durations of 6 minutes, 30 minutes, 6 hours, and 24 hours at atrial rates of 190 and 250 beats/min. RESULTS: Of 5769 AHREs >6 minutes and >190 beats/min, 82.7% were true AT/AF and 17.3% were false positives (predominantly due to repetitive non-re-entrant ventriculoatrial synchrony). False positives dropped to 6.8%, 3.3%, and 1.8% when the threshold duration was increased to 30 minutes, 6 hours, and 24 hours, respectively. Increasing the threshold heart rate to 250 beats/min added little to the positive predictive value when longer threshold durations were used. CONCLUSIONS: By using a cutoff of >6 minutes and >190 beats/min, the rate of false-positive AHREs is 17.3%, making physician review of electrograms essential. For AHREs lasting >6 hours, the rate of false positives is 3.3%, making physician review less crucial.
Type:
Journal article
Language:
English
Published in:
Heart Rhythm, 2012, Vol 9, Issue 8, p. 1241-6
Main Research Area:
Medical science
Publication Status:
Published
Review type:
Peer Review
Submission year:
2012
Scientific Level:
Scientific
ID:
228482565

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • University southern denmark

Metrics

Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en