Patient-specific scatter correction in clinical cone beam computed tomography imaging made possible by the combination of Monte Carlo simulations and a ray tracing algorithm

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Slot Thing, Rune ;
    Close
    Orcid logo0000-0002-2683-2847
    Oncology, Department of Clinical Research, Faculty of Health Sciences, SDU
  • Bernchou, Uffe ;
    Close
    Orcid logo0000-0002-5309-2696
    Oncology, Department of Clinical Research, Faculty of Health Sciences, SDU
  • Mainegra-Hing, Ernesto ;
    Close
    unknown
  • Brink, Carsten
    Close
    Orcid logo0000-0003-3906-1962
    Oncology, Department of Clinical Research, Faculty of Health Sciences, SDU
DOI:
10.3109/0284186X.2013.813641
Abstract:
Abstract Purpose. Cone beam computed tomography (CBCT) image quality is limited by scattered photons. Monte Carlo (MC) simulations provide the ability of predicting the patient-specific scatter contamination in clinical CBCT imaging. Lengthy simulations prevent MC-based scatter correction from being fully implemented in a clinical setting. This study investigates the combination of using fast MC simulations to predict scatter distributions with a ray tracing algorithm to allow calibration between simulated and clinical CBCT images. Material and methods. An EGSnrc-based user code (egs_cbct), was used to perform MC simulations of an Elekta XVI CBCT imaging system. A 60keV x-ray source was used, and air kerma scored at the detector plane. Several variance reduction techniques (VRTs) were used to increase the scatter calculation efficiency. Three patient phantoms based on CT scans were simulated, namely a brain, a thorax and a pelvis scan. A ray tracing algorithm was used to calculate the detector signal due to primary photons. A total of 288 projections were simulated, one for each thread on the computer cluster used for the investigation. Results. Scatter distributions for the brain, thorax and pelvis scan were simulated within 2% statistical uncertainty in two hours per scan. Within the same time, the ray tracing algorithm provided the primary signal for each of the projections. Thus, all the data needed for MC-based scatter correction in clinical CBCT imaging was obtained within two hours per patient, using a full simulation of the clinical CBCT geometry. Conclusions. This study shows that use of MC-based scatter corrections in CBCT imaging has a great potential to improve CBCT image quality. By use of powerful VRTs to predict scatter distributions and a ray tracing algorithm to calculate the primary signal, it is possible to obtain the necessary data for patient specific MC scatter correction within two hours per patient.
Type:
Journal article
Language:
English
Published in:
Acta Oncologica, 2013, Vol 52, Issue 7, p. 1477-83
Main Research Area:
Medical science
Publication Status:
Published
Review type:
Peer Review
Submission year:
2013
Scientific Level:
Scientific
ID:
245653155

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • University southern denmark

Metrics

Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • Open Access
    • Overview
    • Development
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and privacy policy

Copyright © 1998–2018.

Fivu en