Thermal plumes in ventilated rooms

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Kofoed, Peter ;
    Close
    unknown
  • Nielsen, Peter V.
    Close
    Division of Architectural Engineering, Department of Civil Engineering, The Faculty of Engineering and Science, Aalborg University
Subtitle:
Measurements in stratified surroundings and analysis by use of an extrapolation method
Abstract:
The design of a displacement ventilation system involves determination of the flow rate in the thermal plumes. The flow rate in the plumes and the vertical temperature gradient influence each other, and they are influenced by many factors. This paper shows some descriptions of these effects. Free turbulent plumes from different heated bodies are investigated. The measurements have taken place in a full-scale test room where the vertical temperature gradient have been changed. The velocity and the temperature distribution in the plume are measured. Large scale plume axis wandering is taken into account and the temperature excess and the velocity distribution are calculated by use of an extrapolation method. In the case with a concentrated heat source (dia 50mm, 343W) and nearly uniform surroundings the model of a plume above a point heat source is verified. It represents a borderline case with the smallest entrainment factor and the smallest angle of spread. Due to the measuring method and data processing the velocity and temperature excess profiles are observed more narrowly than those reported by previous authors. In the case with an extensive heat source (dia 400mm, lOOW) the model of a plume above a point heat source cannot be used. This is caused either by the way of generating the plume including a long intermediate region or by the environmental conditions where vertical temperature gradients are present. The flow has a larger angle of spread and the entrainment factor is greather than for a point heat source. The exact knowledge of the vertical temperature gradient is essential to predict the flow propagation due to its influence on the entrainment, e.g. in an integral method of plume calculation • Since the flow from different heated bodies is individual full-scale measurements seem to be the only possible approach to obtain the volume flow in: thermal plumes in ventilated rooms.
Type:
Conference paper
Language:
English
Published in:
Roomvent '90, International Conference on Engineering Aero- and Thermodynamics of Ventilated Rooms, Oslo, June 1990, 1990
Keywords:
Thermal Plooms; Ventilation; vertical displacement
Main Research Area:
Science/technology
Publication Status:
Published
Review type:
Peer Review
Conference:
Roomvent´90, 1990
Publisher:
Otto Falch Hurtigtrykk
Submission year:
1990
Scientific Level:
Scientific
ID:
2398074900
Checking for on-site access...

On-site access

At institution

  • Aalborg university.en
Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and Personal Data
  • Open Access
    • The Danish Open Access Indicator

Copyright © 1998–2018.

Fivu en