{"controller"=>"catalog", "action"=>"show", "id"=>"239720073"}
  • EN
  • DA

Danish NationalResearch Database

  • Search Publications & Researchers
  • Open Access Indicator
  • Publications
  • Researchers
Example Finds records
water{} containing the word "water".
water supplies"{}" containing the phrase "water supplies".
author:"Doe, John"author:"{}" containing the prase "Doe, John" in the author field.
title:IEEEtitle:{} containing the word "IEEE" in the title field.
Need more help? Advanced search tutorial
  • Selected (0)
  • History

Displaced dual-mode imaging with desorption electrospray ionization for simultaneous mass spectrometry imaging in both polarities and with several scan modes

    • Save to Mendeley
    • Export to BibTeX
    • Export to RIS
    • Email citation
Authors:
  • Janfelt, Christian ;
    Close
    Analytical Biosciences, Department of Pharmacy, Faculty of Health and Medical Sciences, Københavns Universitet
  • Wellner, Niels ;
    Close
    Department of Drug Design and Pharmacology, Faculty of Pharmaceutical Sciences, Københavns Universitet
  • Hansen, Harald S ;
    Close
    Orcid logo0000-0001-7360-7418
    Molecular and Cellular Pharmacology, Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences, Københavns Universitet
  • Hansen, Steen Honore'
    Close
    Department of Pharmacy, Faculty of Pharmaceutical Sciences, Københavns Universitet
DOI:
10.1002/jms.3166
Abstract:
Displaced dual-mode imaging (DDI) is introduced as a method for simultaneous imaging in positive and negative-ion mode on the same sample with desorption electrospray ionization imaging, as well as a method for simultaneous imaging in full-scan and tandem mass spectrometry (MS/MS) mode. DDI is performed by using a smaller row distance in the y-direction than the desired image resolution and recording for example every second row in positive-ion mode and the other half of the rows in negative-ion mode, thus resulting in two separate images. This causes some degree of oversampling, which is thus utilized to obtain complementary mass spectrometric of the sample. Imaging with both polarities is exemplified on an imprint of a Hypericum perforatum leaf containing secondary metabolites which ionize in both polarites and a mouse kidney containing phospholipids which ionize in positive or negative mode only. Simultaneous full-scan and MS/MS imaging was demonstrated on the same mouse kidney, as the mouse had been given a relatively low dose of the antidepressive drug amitriptyline. While the full-scan data allowed imaging of the endogenous phospholipids, the drug and its metabolites were only visible in the MS/MS images. The latter approach is useful, for example in whole-body imaging experiments where the full-scan data gives an overview of the tissue, and the MS/MS mode provides the sensitivity to image trace amounts of drugs and metabolites. Copyright © 2013 John Wiley & Sons, Ltd.
Type:
Journal article
Language:
English
Published in:
Journal of Mass Spectrometry, 2013, Vol 48, Issue 3, p. 361-6
Main Research Area:
Medical science
Publication Status:
Published
Review type:
Peer Review
Submission year:
2013
Scientific Level:
Scientific
ID:
239720073

Full text access

  • Doi Get publisher edition via DOI resolver
Checking for on-site access...

On-site access

At institution

  • Copenhagen university.en

Metrics

Feedback

Sitemap

  • Search
    • Statistics
    • Tutorial
    • Data
    • FAQ
    • Contact
  • Open Access
    • Overview
    • Development
    • FAQ
    • Contact
  • About
    • Institutions
    • Release History
    • Cookies and privacy policy

Copyright © 1998–2018.

Fivu en